Select Page

CP-0512

CHF 0.00

CentriPure 1500 – Z25M Columns

Gel filtration column for purification and desalting of proteins larger than 5 kDa or nucleic acids longer than 10 bp/nt. Processes sample volumes of 150 mL.

Description

High-Volume Gravity-Flow Desalting with CentriPure 1500 – Z25M

CentriPure 1500 – Z25M Columns are designed for efficient purification and desalting of proteins and nucleic acids in high-volume applications. These gravity-flow gel filtration columns are ideal for separating large biomolecules (such as antibodies, enzymes, or long nucleic acids) from smaller contaminants like salts, dyes, biotin, and other low molecular weight compounds. Their high recovery rate and >99.99% removal efficiency make them a powerful alternative to time-consuming dialysis or TFF.
The columns are packed with Zetadex-25 Medium, a cross-linked beaded dextran matrix developed by emp BIOTECH, optimized for rapid and reproducible separations. Designed to process up to 150 mL of sample in under 15 minutes, the column ensures minimal dilution and high throughput with consistent results across applications.

Performance Highlights
  • Efficient removal of small molecules with >99.99% desalting efficiency
  • 85% recovery of proteins and nucleic acids
  • Sample volumes up to 150 mL processed in <15 minutes
  • Rapid, gravity-based purification with no need for centrifugation or vacuum
  • Ideal for antibodies, enzymes, DNA, RNA, and nanoparticles ≥ 2 nm
  • Fractionation range: ~5 kDa for proteins / ~10 base pairs for nucleic acids
Specifications
  • Matrix: Zetadex-25 Medium
  • Bead size: 50–150 µm
  • Sample volume: up to 150 mL
  • Bed volume: 195 mL
  • Recommended buffer volume: 195 mL
  • Dilution factor: ~1.5×
  • Flow type: Gravity
  • Processing time: <15 minutes
  • Format: Ready-to-use, single-use column
  • Manufactured by: emp BIOTECH, Berlin-Buch
Applications
  • Desalting of proteins, nucleic acids, and nanoparticles
  • Buffer exchange
  • Removal of dyes, salts, haptens, and unreacted small molecules
  • High-throughput sample preparation for downstream processing
Why Choose CentriPure 1500 – Z25M?

CentriPure 1500 – Z25M is the ideal solution for laboratories and production environments requiring fast, scalable purification of high-volume samples. The column’s gravity-based design eliminates the need for specialized equipment while delivering unmatched desalting efficiency and recovery. Its compatibility with a broad range of biomolecules and buffers ensures flexible integration into existing protocols. Whether you’re performing preparative cleanup or downstream processing, this column provides dependable, high-yield results with exceptional ease of use.

Additional information

Pack Size

Safety Information

Hazard Classifications

Skin Sensitization, Category 1 (Skin Sens. 1)

Hazard Statements

H317 – May cause an allergic skin reaction.

Precautionary Statements

P262 – Do not get in eyes, on skin, or on clothing.

P280 – Wear protective gloves/protective clothing/eye protection/face protection.

P302+P352 – IF ON SKIN: Wash with plenty of water/…

P305+P351+P338 – IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Signal Word

Warning

WGK

WGK 3

Storage Class Code

  • 10 – Flammable liquids if not LGK 3A or 3B

  • 11 – Flammable solids

  • 12 – Non-flammable liquids in non-flammable packages

  • 13 – Non-flammable solids in non-flammable packages

Transport Information

ADR / RID (Road & Rail): Not dangerous goods

IATA-DGR (Air Transport): Not dangerous goods

IMDG Code (Sea Transport): Not dangerous goods

Downloads

Material safety data sheet
Product specification sheet
User instructions
Zetadex Gel Filtration Catalog
Biomolecule Purification, Catalog 12/2024